Device Type
UPS - external
Battery Enclosure Type
Internal
Localisation
United States
Input Voltage Range
AC 90 - 140 V
Frequency Provided
60 Hz ± 3Hz
Frequency Required
60 Hz ± 3Hz
Input Connectors
1 x power NEMA 5-15P
Power Output Connectors Details
4 x power NEMA 5-15R (UPS and surge) ¦ 4 x power NEMA 5-15R (surge)
Output Voltage
AC 120 V 60 Hz
Max Electric Current
12 A
Power Capacity
390 watt / 650 VA
Dataline Surge Protection
Network - RJ-45
Output Waveform
Stepped approximation to a sinewave
Surge Energy Rating
340 joules
Circuit Protection
Circuit breaker
Run Time (Up To)
29.2 min at 100 Watts ¦ 11.6 min at 200 Watts ¦ 5.9 min at 300 Watts ¦ 3.3 min at full load ¦ 12 min at half load
Remote Management Interface
USB
Interfaces
1 x management (USB) - 4 pin USB Type B
Cables Included
Power cable - integrated - 1.52 m ¦ USB cable
Equipment Protection Value
75000 US Dollars
Features
Audible alarm, LED indicators, cold-start function, automatic self-test, predicitive failure notification
Compliant Standards
CSA C22.2 No. 107.1, FCC Part 15 Class B, FCC Part 68, NOM, TUV C, UL 1778, RoHS, REACH
Pricing Type
APC Take-Back
Sustainability Information
Service & Support
Limited warranty - replace or repair - 3 years ¦ Limited warranty - battery - 1 year
Min Operating Temperature
0 °C
Max Operating Temperature
40 °C
Humidity Range Operating
5 - 95%
Dimensions & Weight (Shipping)
Compatibility Information
Designed For
P/N: ACF600, AR106, AR106SH4, AR106SH6, AR109SH4, AR109SH6, AR112, AR112SH4, AR112SH6, AR8213, NBWL0356A